Vol: 51(65) No: 4 / December 2006 The Use of Complementary Sequences for Linear Invariant System Testing Constantin Cosovan Computers Department, Faculty of Automation and Computers, “Politehnica” University of Timisoara, V. Parvan 2, Timisoara, Romania, phone: 40 256 300223, e-mail: constantin.cosovan@cs.upt.ro Gabriela Prostean Faculty of Management in Production and Transportation, "Politehnica" University of Timisoara, Remus 14, Timisoara, Romania, phone: 40 256 404039, e-mail: gabrielaprostean@yahoo.com Keywords: complementary, sequence, invariant, linear system, testing, self correlation, reflectometry. Abstract Complementary sequences (Golay series) are well suited for the testing of time-invariant linear systems, for radar and optic reflectometry and for multislit spectrometers. The effect of applying a delta pulse can be obtained, without having to strain the system. At the same time, a better compromise between the resolution and the signal to noise ratio is obtained. References [1] M.J.E.Golay, “Multislit spectometry”, J. Opt. Soc. Am., vol.39, p.437, 1949. [2] M.J.E.Golay, “Static multislit spectometry and its application to the panoramic display of infrared spectra”, J. Opt. Soc. Am., vol.41, p.468, 1951. [3] M.J.E.Golay, “Complementary Series”, I.R.E. Transactions on Informations Theory, pp. 82-87, 1961. [4] F. Sischka, S.A Newton, N. Nazarathy, “Complementary Correlation Optical Time – Domein Reflectometry”, H.P. – Journal, pp. 14-21, 1988. |